VELOSIT WP 100 is a rigid cementitious coating that bonds to suitable concrete and masonry. It provides surface waterproofing on the selected face of the structure, as part of a complete waterproofing system.

Product at a glance
MaterialRigid cementitious coating
BondTo a sound mineral substrate
Water exposurePositive- or negative-side design

Positive-side waterproofing

Conceptual cutaway of a rigid coating bonded to a mineral substrate. Solid blue arrows meet the water-facing coating before the substrate. Pins identify 1 water direction, 2 coating and 3 substrate.
Conceptual section; not to scale.
  1. 1 Water reaches the coating first
  2. 2 Rigid bonded coating
  3. 3 Mineral substrate

Negative-side waterproofing

Conceptual cutaway with rigid coating on the side of the mineral substrate opposite the water. Dashed blue arrows travel through the substrate toward the coating. Pin 1 identifies water direction and pin 2 the coating.
Conceptual section; not to scale.
  1. 1 Water approaches through the substrate
  2. 2 Rigid bonded coating on the opposite face

Uses and benefits

Bonded surface waterproofing

Forms a waterproofing layer on suitable concrete and masonry, with the coating bonded directly to the mineral substrate.

Water-facing and reverse-side layouts

Positive- and negative-side arrangements place the coating on different faces of the structure. Each arrangement requires its own design assessment.

Material and application

Suitable surfacesConcrete and suitable masonry with a sound, prepared mineral surface.
Positive sideWater reaches the coating before the mineral substrate.
Negative sideWater reaches the substrate before the coating on the opposite face.

Application notes

The rigid coating does not bridge moving joints. Joints, moving cracks and penetrations need compatible details, and active leaks need separate treatment.

Substrate condition, existing coatings, preparation, exposure and subsequent finishes remain part of the complete system design. Any required project approvals remain to be confirmed.

No pressure rating, coat count or coating thickness is specified in this overview.

SEED ChemicalsVELOSIT

Product guide

Rigid cementitious surface waterproofing

VELOSIT WP 100

VELOSIT WP 100 is a rigid cementitious coating that bonds to suitable concrete and masonry. It provides surface waterproofing on the selected face of the structure, as part of a complete waterproofing system.

Product at a glance
MaterialRigid cementitious coating
BondTo a sound mineral substrate
Water exposurePositive- or negative-side design

Bonded waterproofing on a mineral surface

VELOSIT WP 100 is a rigid cementitious coating that bonds to suitable concrete and masonry. It provides surface waterproofing on the selected face of the structure, as part of a complete waterproofing system.

Positive-side waterproofing

Conceptual cutaway of a rigid coating bonded to a mineral substrate. Solid blue arrows meet the water-facing coating before the substrate. Pins identify 1 water direction, 2 coating and 3 substrate.
Water reaches the coating before the mineral substrate. Conceptual section; not to scale.
  1. 1 Water reaches the coating first
  2. 2 Rigid bonded coating
  3. 3 Mineral substrate
Open higher-resolution detail ↗

Negative-side waterproofing

Conceptual cutaway with rigid coating on the side of the mineral substrate opposite the water. Dashed blue arrows travel through the substrate toward the coating. Pin 1 identifies water direction and pin 2 the coating.
Water reaches the substrate before the coating on the opposite face. Conceptual section; not to scale.
  1. 1 Water approaches through the substrate
  2. 2 Rigid bonded coating on the opposite face
Open higher-resolution detail ↗

Uses and benefits

Bonded surface waterproofing

Forms a waterproofing layer on suitable concrete and masonry, with the coating bonded directly to the mineral substrate.

Water-facing and reverse-side layouts

Positive- and negative-side arrangements place the coating on different faces of the structure. Each arrangement requires its own design assessment.

Material and application

Suitable surfacesConcrete and suitable masonry with a sound, prepared mineral surface.
Positive sideWater reaches the coating before the mineral substrate.
Negative sideWater reaches the substrate before the coating on the opposite face.

Application notes

The rigid coating does not bridge moving joints. Joints, moving cracks and penetrations need compatible details, and active leaks need separate treatment.

Substrate condition, existing coatings, preparation, exposure and subsequent finishes remain part of the complete system design. Any required project approvals remain to be confirmed.

No pressure rating, coat count or coating thickness is specified in this overview.

Project selection and technical detail

Waterproofing from the selected face

Select the coating face around the water direction, accessible mineral substrate and complete waterproofing detail. Positive- and negative-side exposure each require project assessment.

Rigid bonded waterproofing coating

Conceptual coating sections; not to scale.

Water reaches the coating before the mineral substrate.

Water reaches the substrate before the coating on the opposite face.

Product reference
MaterialRigid cementitious coating
InterfaceBonded to a mineral substrate
SelectionWater direction and complete detailing

Confirm the supplied product and the complete project specification with SEED.

Where it fits

  1. 01

    Protect a mineral surface

    For assessed concrete or masonry requiring a bonded surface-waterproofing coating.

Questions before specification

  1. 01

    Identify the water route

    Record the source and direction of water, the accessible face and the surrounding construction.

  2. 02

    Assess the substrate

    Check soundness, existing coatings, active leaks, cracks and movement before selecting the system.

Coordinate the complete system

  1. 01

    Detail discontinuities separately

    Joints, penetrations and moving cracks require their own compatible details; a rigid coating is not a moving-joint bridge.

  2. 02

    Confirm the complete specification

    Confirm the supplied product, pressure-side design, preparation and any required approvals with the project specialist.

Application guidance

Obtain the matched technical and safety sheets and complete project application instructions for the supplied VELOSIT WP 100 before work.

Discuss your project →

Use limits

Active leaks need separate treatment.

Positive- and negative-side arrangements require separate design assessment. No pressure rating, coat count or coating thickness is specified in this overview.

Technical and safety information.

Read the product overview and request the technical and safety sheets for your supplied components.

VELOSIT WP 100 manufacturer technical data sheet · edition 1322

Product properties and application guidance · 1322 · en

Open technical sheet ↗

VELOSIT WP 100 safety data sheet for the supplied product

Handling, storage and safety information

Request safety sheet →

Talk to SEED about your project

Ask for product guidance and the technical or safety sheets you need. Have these details ready when you contact SEED.

  • Substrate and existing condition
  • Water source, direction and accessible face
  • Leaks, cracks, joints and penetrations
  • Required exposure and subsequent finish
  • Supplied product and project specification
  • Matching technical and safety information

Product selection guide. This overview does not replace the matched technical data sheet, safety data sheet or project instructions.